Visible Spectrophotometers

SI-102 Microprocessor Visible Spectrophotometer

Brand NameSpectronics India
Model No.SI-102
Range340 to 960 nm
Resolution0.1%T, 0.001 Abs, conc.1
Output%T: 0 t0 100%, Abs. 0 to 1.999, Conc. 0 to 1999
DetectorSilicon Photodiode
Light Source6V, 10W. l Tungsten Halogen Lamp
Monochromator600 Lines / mm holographic grating
Sample Holder10 mm (50mm path Length in Model SI-104 only)
Spectral Bandwidth5 mm
Wave Length Resolution1 nm
Wave Length Resolution1 nm
Wave Length Accuracy+1 nm
Repeatability±2 nm
Display3 1/2 Digit LED display for results & 3 digit display for Wavelength
Power230V±10% AC 50 Hz
DimensionsL490 x B300 x H190 mm
Weight8 kg (approx.)
LocationWorldwide

SI-105 Microprocessor Visible Spectrophotometer

Brand NameSpectronics India
Model NoSI-105
Wavelength AccuracyTugsten Halogen Lamp 20W/12V
Wavelength Repeatability≤1nm
Transmittance Accuracy±0.5%
Transmittance Repeatability≤0.2%
Spectrum Bandwidth5nm
Stray Light≤0.5% (at 360nm, NaN02 Light Current Drift 0.5% / 3 min
Stray Light≤0.5% (at 360nm, NaN02 Light Current Drift 0.5% / 3 min
Dark Current Drift0.2% / 3 min Cell Holder
Dimensions10 mm Nett
Weight27Kgs
Wavelength Range325 – 1000 nm
LocationWorldwide

SI-106 Microprocessor Visible Spectrophotometer

ModelSI-106
Wavelength Rang (nm)340-1000
Trasmittance Range0-199.9
Absorbance Range A0-1.999
Sccope of Concentration Display0-1.999
Wavelength Accuracy (nm)+3
Photometric Accuracy1.5
Bandwidth (nm)1nm
Stray Light+0.2% (T)
Absorbance Repeatability %+0.2% (T)
Stray ligh %1.0
Noise %0%-0.3,100%-1.0
Overall Dimensions (nm)460X350X180
Weight (Kg)8kgs
DisplayThe LCD screen with backlight
LocationWorldwide

SI-120 Microprocessor Visible Spectrophotometer

Model No.SI-120
Wevelegth Range325 to 1000 nm
Light Source LampTugsten Halogen Lamp 20W/12V
Wevelegth Accuracy+2nm
Wevelegth Reproducibility1nm
Band Width2nm
Photometric Accuracy+0.5% (T)
Photometric Reproducibility0.2% (T)
Stray Light+0.2% (T)
Noise+0.2% (T)
Size(LXWXH) Main Unit: 370X320X190mm
Carton450X420X280mm
WeightN.W-7KG G.W-9.5 KG
Power Requirement220V/110V+10% 50/60 Hz
InterfaceRS232 serial & parallel interface
LocationWorldwide
ModelSI-106
Wavelength Rang (nm)340-1000
Trasmittance Range0-199.9
Absorbance Range A0-1.999
Sccope of Concentration Display0-1.999
Wavelength Accuracy (nm)+3
Photometric Accuracy1.5
Bandwidth (nm)1nm
Stray Light+0.2% (T)
Absorbance Repeatability %+0.2% (T)
Stray ligh %1.0
Noise %0%-0.3,100%-1.0
Overall Dimensions (nm)460X350X180
Weight (Kg)8kgs
DisplayThe LCD screen with backlight
LocationWorldwide